# # This file is part of SickGear. # # SickGear is free software: you can redistribute it and/or modify # it under the terms of the GNU General Public License as published by # the Free Software Foundation, either version 3 of the License, or # (at your option) any later version. # # SickGear is distributed in the hope that it will be useful, # but WITHOUT ANY WARRANTY; without even the implied warranty of # MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the # GNU General Public License for more details. # # You should have received a copy of the GNU General Public License # along with SickGear. If not, see . from __future__ import with_statement import codecs import datetime import logging import glob import os import re import sys import threading import time import zipfile from logging.handlers import TimedRotatingFileHandler import sickgear from . import classes from .sgdatetime import timestamp_near from sg_helpers import md5_for_text, remove_file_perm # noinspection PyUnreachableCode if False: from typing import AnyStr, Union try: # noinspection PyUnresolvedReferences from lib.send2trash import send2trash except ImportError: pass # ERROR = 40, WARNING = 30, INFO = 20, DEBUG = 10 ERROR = logging.ERROR WARNING = logging.WARNING MESSAGE = logging.INFO DEBUG = logging.DEBUG DB = 5 reverseNames = {u'ERROR': ERROR, u'WARNING': WARNING, u'INFO': MESSAGE, u'DEBUG': DEBUG, u'DB': DB} # suppress output with this handler class NullHandler(logging.Handler): def emit(self, record): pass class SBRotatingLogHandler(object): def __init__(self, log_file): """ :param log_file: log file :type log_file: AnyStr """ self.log_file = log_file # type: AnyStr self.log_file_path = log_file # type: AnyStr self.h_file = None self.h_console = None self.console_logging = False # type: bool self.log_lock = threading.Lock() self.log_types = ['sickgear', 'tornado.application', 'tornado.general', 'subliminal', 'adba', 'encodingKludge', 'tvdb.api', 'TVInfo'] self.external_loggers = ['sg.helper', 'api_trakt', 'api_trakt.api'] self.log_types_null = ['tornado.access'] def __del__(self): pass def close_log(self, handler=None): """ :param handler: :type handler: """ handlers = [] if not handler: if None is not self.h_console: handlers = [self.h_console] handlers += [self.h_file] elif not isinstance(handler, list): handlers = [handler] for handler in handlers: for logger_name in self.log_types + self.log_types_null + self.external_loggers: logging.getLogger(logger_name).removeHandler(handler) if type(handler) != type(logging.StreamHandler()): # check exact type, not an inherited instance handler.flush() handler.close() def init_logging(self, console_logging=False): """ :param console_logging: console logging :type console_logging: bool """ self.console_logging |= console_logging self.log_file_path = os.path.join(sickgear.LOG_DIR, self.log_file) # get old handler for post switch-over closure old_h_file = old_h_console = None if self.h_file or self.h_console: if self.h_file: old_h_file = self.h_file if self.h_console: old_h_console = self.h_console # add a new logging level DB logging.addLevelName(5, 'DB') if self.console_logging: # get a console handler to output INFO or higher messages to sys.stderr h_console = logging.StreamHandler() if None is not h_console.stream: h_console.setLevel((logging.INFO, logging.DEBUG)[sickgear.DEBUG]) h_console.setFormatter(DispatchingFormatter(self._formatters(), logging.Formatter('%(message)s'), )) self.h_console = h_console # add the handler to the root logger for logger_name in self.log_types + self.external_loggers: logging.getLogger(logger_name).addHandler(h_console) for logger_name in self.log_types_null: logging.getLogger(logger_name).addHandler(NullHandler()) h_file = TimedCompressedRotatingFileHandler(self.log_file_path, logger=self) h_file.setLevel(reverseNames[sickgear.FILE_LOGGING_PRESET]) h_file.setFormatter(DispatchingFormatter(self._formatters(False), logging.Formatter('%(message)s'), )) self.h_file = h_file for logger_name in self.external_loggers: logging.getLogger(logger_name).addHandler(h_file) logging.getLogger(logger_name).setLevel(DEBUG) for logger_name in self.log_types: logging.getLogger(logger_name).addHandler(h_file) log_level = (logging.WARNING, logging.DEBUG)[sickgear.DEBUG] for logger_name in [x for x in self.log_types if 'sickgear' != x]: logging.getLogger(logger_name).setLevel(log_level) logging.getLogger('sickgear').setLevel(DB) # as now logging in new log folder, close old handlers if old_h_file: self.close_log(old_h_file) if old_h_console: self.close_log(old_h_console) def _formatters(self, log_simple=True): """ :param log_simple: simple log :type log_simple: bool :return: """ fmt = {} for logger_name in self.log_types + self.external_loggers: source = ((re.sub(r'(.*\.\w\w\w).*$', r'\1', logger_name), logger_name)['sg.' in logger_name] .upper() + ' :: ', '')['sickgear' == logger_name] fmt.setdefault(logger_name, logging.Formatter( '%(asctime)s %(levelname)' + ('-8', '')[log_simple] + 's ' + source + '%(message)s', ('%Y-%m-%d ', '')[log_simple] + '%H:%M:%S')) return fmt def log(self, to_log, log_level=MESSAGE): # type: (Union[AnyStr, list], int) -> None """Log an item, or a list of items using log_lock so to_log list items are continuous in output. :param to_log: log message, list of log messages :param log_level: log level """ with self.log_lock: self.output_log((to_log, [to_log])[not isinstance(to_log, list)], log_level) @staticmethod def output_log(log_list, log_level=MESSAGE): # type: (list, int) -> None """ :param log_list: log message :param log_level: log level """ mem_key = 'logger' for to_log in log_list: log_id = md5_for_text(to_log) now = int(timestamp_near(datetime.datetime.now())) expired = now > sickgear.MEMCACHE.get(mem_key, {}).get(log_id, 0) sickgear.MEMCACHE[mem_key] = {} sickgear.MEMCACHE[mem_key][log_id] = 2 + now if not expired: continue out_line = '%s :: %s' % (threading.current_thread().name, to_log) sb_logger = logging.getLogger('sickgear') setattr(sb_logger, 'db', lambda *args: sb_logger.log(DB, *args)) # sub_logger = logging.getLogger('subliminal') # tornado_logger = logging.getLogger('tornado') try: if DEBUG == log_level: sb_logger.debug(out_line) elif MESSAGE == log_level: sb_logger.info(out_line) elif WARNING == log_level: sb_logger.warning(out_line) elif ERROR == log_level: sb_logger.error(out_line) # add errors to the UI logger classes.ErrorViewer.add(classes.UIError(out_line)) elif DB == log_level: sb_logger.db(out_line) else: sb_logger.log(log_level, out_line) except ValueError: pass def log_error_and_exit(self, error_msg): """ :param error_msg: error message :type error_msg: AnyStr """ log(error_msg, ERROR) if not self.console_logging: sys.exit(error_msg.encode(sickgear.SYS_ENCODING, 'xmlcharrefreplace')) else: sys.exit(1) @staticmethod def reverse_readline(filename, buf_size=4096): """a generator that returns the lines of a file in reverse order :param filename: file name :type filename: AnyStr :param buf_size: buffer size :type buf_size: int or long """ with codecs.open(filename, 'r', encoding='utf-8', errors='replace') as fh: segment = None offset = 0 fh.seek(0, os.SEEK_END) file_size = remaining_size = fh.tell() while 0 < remaining_size: offset = min(file_size, offset + buf_size) fh.seek(file_size - offset) buf = fh.read(min(remaining_size, buf_size)) remaining_size -= buf_size lines = buf.split('\n') # the first line of the buffer is probably not a complete line, # so save it and append it to the last line of the next buffer # we read if None is not segment: # if the previous chunk starts right from the beginning of line # do not concat the segment to the last line of new chunk # instead, yield the segment first if buf[-1] != '\n': lines[-1] += segment else: yield segment + '\n' segment = lines[0] for index in range(len(lines) - 1, 0, -1): if len(lines[index]): yield lines[index] + '\n' yield None is not segment and segment + '\n' or '' class DispatchingFormatter(object): def __init__(self, formatters, default_formatter): self._formatters = formatters self._default_formatter = default_formatter def __del__(self): pass def format(self, record): formatter = self._formatters.get(record.name, self._default_formatter) return formatter.format(record) class TimedCompressedRotatingFileHandler(TimedRotatingFileHandler): def __init__(self, log_file_path, logger=None, when='midnight', interval=1, backup_count=16, encoding='utf-8', delay=False, utc=False): super(TimedCompressedRotatingFileHandler, self).__init__(log_file_path, when, interval, backup_count, encoding, delay, utc) self.logger_instance = logger """ Extended version of TimedRotatingFileHandler that compress logs on rollover. by Angel Freire """ def doRollover(self): """ do a rollover; in this case, a date/time stamp is appended to the filename when the rollover happens. However, you want the file to be named for the start of the interval, not the current time. If there is a backup count, then we have to get a list of matching filenames, sort them and remove the one with the oldest suffix. This method is modified from the one in TimedRotatingFileHandler. example: logger.TimedCompressedRotatingFileHandler(sickgear.logger.sb_log_instance.log_file_path, when='M', interval=2, logger=sickgear.logger.sb_log_instance).doRollover() """ if not self.logger_instance: return # get the time that this sequence started at t = self.rolloverAt - self.interval start_time = time.localtime(t) file_name = self.baseFilename.rpartition('.')[0] dfn = '%s_%s.log' % (file_name, time.strftime(self.suffix, start_time)) self.delete_logfile(dfn) self.logger_instance.close_log() self.logger_instance.h_file = self.logger_instance.h_console = None try: self.stream.close() except AttributeError: pass try: os.rename(self.baseFilename, dfn) except (BaseException, Exception): pass self.logger_instance.init_logging() if self.encoding: self.stream = codecs.open(self.baseFilename, 'w', self.encoding) else: self.stream = open(self.baseFilename, 'w') zip_name = '%s.zip' % dfn.rpartition('.')[0] self.delete_logfile(zip_name) with zipfile.ZipFile(zip_name, 'w', zipfile.ZIP_DEFLATED) as zip_fh: zip_fh.write(dfn, os.path.basename(dfn)) self.delete_logfile(dfn) if 0 < self.backupCount: # find the oldest log file and delete it # phase out files named sickgear.log in favour of sickgear.logs over backup_count days all_names = glob.glob(file_name + '_*') \ + glob.glob(os.path.join(os.path.dirname(file_name), 'sickbeard_*')) if len(all_names) > self.backupCount: all_names.sort() self.delete_logfile(all_names[0]) self.rolloverAt = self.rolloverAt + self.interval @staticmethod def delete_logfile(filepath): """ :param filepath: file path :type filepath: AnyStr """ if os.path.exists(filepath): if sickgear.TRASH_ROTATE_LOGS: try: send2trash(filepath) except OSError: pass else: remove_file_perm(filepath) sb_log_instance = SBRotatingLogHandler('sickgear.log') def debug(to_log): # type: (AnyStr) -> None """ log message flagged as debug :param to_log: log message """ sb_log_instance.log(to_log, DEBUG) def warning(to_log): # type: (AnyStr) -> None """ log message flagged as warning :param to_log: log message """ sb_log_instance.log(to_log, WARNING) def error(to_log): # type: (AnyStr) -> None """ log message flagged as error :param to_log: log message """ sb_log_instance.log(to_log, ERROR) def log(to_log, log_level=MESSAGE): # type: (Union[AnyStr, list], int) -> None """ :param to_log: log message :param log_level: log level """ sb_log_instance.log(to_log, log_level) def log_error_and_exit(error_msg): """ :param error_msg: error message :type error_msg: AnyStr """ sb_log_instance.log_error_and_exit(error_msg) def load_log(load_msg, to_log, log_level=MESSAGE): """ logs messages and adds log_level = MESSAGE messages as progress to loading page :param load_msg: base loading page message :param to_log: message to log to file and as progress for loading page :param log_level: log level (only level MESSAGE is also output as loading page progress) """ if MESSAGE == log_level: sickgear.classes.loading_msg.set_msg_progress(load_msg, to_log) log(to_log, log_level) def close(): sb_log_instance.close_log() def log_set_level(): if sb_log_instance.h_file: sb_log_instance.h_file.setLevel(reverseNames[sickgear.FILE_LOGGING_PRESET]) def current_log_file(): return os.path.join(sickgear.LOG_DIR, sb_log_instance.log_file)